Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Case Rep Infect Dis ; 2022: 1129832, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387092

RESUMO

Comamonas kerstersii (C. kerstersii) is a Gram-negative bacillus abundant in the environment and rarely implicated in human disease. Previously considered nonpathogenic, its scarcity in literature may be partly due to the unreliability of past phenotypic tests used for its identification. In recent years, the development of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has enabled fast and accurate laboratory identification of C. kerstersii. Since the first report of human infection in 2013, several others have emerged, with most cases involving peritoneal infection. Here, we present a rare case of C. kerstersii bacteremia in an 82-year-old male patient. With no clear predisposing conditions, the source of his infection is unclear. We accompany this report with a review of C. kerstersii bacteremia cases found in the literature.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35286278

RESUMO

This study validated the performance of the reverse transcriptase-polymerase chain reaction (rRT-PCR) based Cepheid Xpert® Xpress SARS-CoV-2 assay against the TIB MOLBIOL E-gene/EAV, a standard laboratory rRT-PCR SARS-CoV-2 assay. Upper and lower respiratory tract samples (nasopharyngeal and nasal swabs, bronchoalveolar lavage, and tracheal aspirate) were obtained from patients suspected to have contracted COVID-19. Results from the Xpert® Xpress and standard rRT-PCR assays were compared for positive and negative agreement and analyzed for precision, reproducibility, 95% confidence intervals, and coefficients of variation. The Xpert® Xpress assay demonstrated 100% agreement with the standard lab rRT-PCR for both upper and lower respiratory tract samples. Both the Xpert® Xpress and lab rRT-CPR identified weakly positive (Ct values 35-39) sample replicates with 100% reproducibility and showed 100% precision in identifying triplicates of upper respiratory tract samples. The single-cartridge Xpert® Xpress system has a short turnaround time and can be employed to improve patient management and hospital bed allocation. Further verification of the system is required before implementation and consideration must be paid to its higher cost and impracticality for high-throughput use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...